Confined space ventilation calculator

Updated October 18, 20263 min tool
1

The space

Units
Shape
ft
ft
ft

Its depth. Only the air above it is purged.

2

The air

The blower's free-air rating. The duct's length and bends take their share off, unless you know the delivered airflow.

CFM

Their airflows add.

ft

About 15% each.

in
CFM

Per blower, ducted. Replaces the estimate.

Set up to
3

The atmosphere

Your first reading and the level you need before entry.

ppm
ppm
Alberta limit
10 ppm 8-hour, 15 ppm ceiling
IDLH
100 ppm
LEL
4% by volume
Density (air = 1)
1.19

Heavier than air: it collects low, in sumps and at the bottom of the space.

ft³/min

Pure gas still entering the space (a leak, sludge off-gassing). Leave blank if the source is isolated.

Loading the 3D view…

0 s in

50 ppm

4

Ventilate for

Before anyone enters

1.8 min

Set by 10.5 air changes (7, plus half for a toxic gas).

Air volume

126ft³

Air delivered

744CFM

74% of the rating.

Dilution time

1.4 min

K = 5

10.5 air changes

1.8 min

Air changes an hour

355

20 or more while occupied.

Air per worker

372CFM

At least 200 CFM.

Target 10 ppmEnter after 1.8 min0.0 min0.6 min1.1 min1.7 min2.2 min544
Duct velocity
2,131 ft/min
Supply throw
20 ft
Duct friction
0.21 in. w.g.
Needed for 20 ACH
42 CFM

The rules · Alberta

  • Oxygen between 19.5% and 23%.
  • No entry or work above 20% LEL (s.162); hot work stops above 20% LEL (s.169).
  • H₂S: 10 ppm 8-hour, 15 ppm ceiling. CO: 25 ppm 8-hour. Exposure limits: OHS Code Schedule 1, Table 2.
  • Ventilate or purge where testing finds a hazardous atmosphere; mechanical ventilation must warn workers if it fails (s.53). Continuous monitoring where the atmosphere may change (s.52).
  • An attendant outside the space and a rescue plan in place before entry.

A summary to plan with. The regulation and your employer's procedures govern.

Test before entry, and keep testing

A purge time is a plan, not a clearance. Test at the top, middle and bottom before anyone enters, and monitor continuously while they work. Supply air pushes contaminants out through every opening: keep the blower intake upwind, away from engines and the opening itself.

This calculator works out how long to ventilate a confined space before anyone goes in. It finds the air volume of the space, the air your blowers really deliver through their duct, and the time to bring your first reading down to a safe level, and it shows the purge in a 3D view of the space.

The purge time formula

Ventilation dilutes a contaminant exponentially: each minute removes a share of what is left. Rearranged for time, the dilution equation is:

Purge time = K × (V ÷ Q) × ln(C₀ ÷ C)

  • V is the volume of air in the space, less any liquid or sludge left in it.
  • Q is the airflow actually delivered into the space, not the blower's free-air rating.
  • C₀ is your first reading and C the level you need. For low oxygen, the calculator dilutes the shortfall below 20.9%.
  • K is the mixing factor: how far real mixing falls short of perfect. It is engineering judgement, from about 3 for an open tank to 8 or more for a pipe or tunnel.

The calculator also applies the blower makers' rule of seven complete air changes, half again for a toxic gas, and uses whichever time is longer. Where gas is still being released, it works out the level the space settles at and the airflow needed to hold it below your target.

Rated airflow is not delivered airflow
Blowers are rated at free air. Every bend and every metre of duct takes some of that away, and three bends in a long run can nearly halve it. Enter the duct and the calculator estimates the loss, or enter the delivered airflow from the maker's ducted rating or a measurement.

Setting up the ventilation

  • Put the blower intake upwind, away from engines, exhaust and the opening of the space.
  • Run supply duct to the far end and the bottom of the space: supply air only reaches about 30 duct diameters.
  • Exhaust where the gas collects: low for H₂S, propane and CO₂, high for methane and ammonia.
  • Use an explosion-proof (intrinsically safe) blower and bonded duct in a flammable atmosphere.
  • Keep ventilating while people are inside, and stop work if the blower stops.

Across Canada

Pick your jurisdiction in the calculator and it sets the targets to that jurisdiction's limits, warns when yours are higher, and lists its rules. In brief:

JurisdictionOxygenFlammable gas for workH₂S limit
Alberta19.5% to 23%Below 20% LEL10 ppm 8-hour, 15 ppm ceiling
British Columbia19.5% to 23%Below 20% LEL10 ppm ceiling
Saskatchewan19.5% to 23%Below 20% LEL10 ppm 8-hour, 15 ppm 15-minute
Manitoba19.5% to 23%Below 10% LEL1 ppm 8-hour, 5 ppm short-term
Ontario19.5% to 23%Below 10% LEL10 ppm 8-hour, 15 ppm short-term (Reg. 833)
Quebec19.5% to 23%Below 5% LEL10 ppm 8-hour, 15 ppm short-term
New Brunswick19.5% to 23%Below 10% LEL10 ppm ceiling
Nova Scotia19.5% to 22.5%Below 10% LEL1 ppm 8-hour, 5 ppm short-term
Prince Edward Island19.5% to 23%Below 10% LEL1 ppm 8-hour, 5 ppm short-term
Newfoundland and Labrador20% to 22%Below 10% LEL1 ppm 8-hour, 5 ppm short-term
Federal (Canada Labour Code)19.5% to 23%Below 10% LEL1 ppm 8-hour, 5 ppm short-term
Yukon19.5% to 23.5%Below 20% LELCheck the current Yukon table
Northwest Territories19.5% to 23%Below 20% LEL10 ppm 8-hour, 15 ppm 15-minute
Nunavut19.5% to 23%Below 20% LEL10 ppm 8-hour, 15 ppm 15-minute

In Alberta

Part 5 of Alberta's OHS Code governs confined spaces: a hazard assessment, a written code of practice, a permit, atmospheric testing before entry and while work goes on, a trained attendant and a rescue plan. Ventilation is one of the controls the assessment chooses. Our hazard assessment and program development services build confined space programs that meet it, and the COR readiness check shows where the rest of your program stands.

Sources: blower makers' purge charts (Air Systems International; Pelsue, citing Bell System Standard ISS10) for seven air changes, half again for toxic gases and 20 air changes an hour; Allegro's published bend ratings; NIOSH Pocket Guide for gas properties; Alberta OHS Code, Schedule 1, for exposure limits. Mixing factors are engineering judgement.

Frequently asked questions

How long should you ventilate a confined space before entry?
Long enough to bring the atmosphere to a safe level and to change the air several times over: blower makers recommend at least seven complete air changes, and half again for a toxic gas. The dilution equation, t = K × (V ÷ Q) × ln(C0 ÷ C), gives the time to bring a reading down to a target. Use the longer of the two, then test before anyone enters.
How do you calculate confined space purge time?
Purge time in minutes = K × volume ÷ airflow × ln(first reading ÷ target). Volume is in cubic feet or cubic metres, airflow in CFM or cubic metres a minute, and K is a mixing factor from about 3 for a tank with good mixing to 8 or more for a long pipe or tunnel. For example, 1,000 ft³ at 800 CFM delivered, K of 5, from 50 ppm to 10 ppm of H₂S: 5 × 1.25 × 1.61 = 10 minutes.
How many air changes per hour does a confined space need?
While people are inside, at least 20 air changes an hour is the common target in blower makers’ charts and ventilation references. Before entry, seven complete air changes is the usual minimum purge. More is better where a contaminant can still be released.
Does a duct reduce a blower’s airflow?
Yes. A blower’s rating is usually at free air, with no duct. Each 90° bend costs roughly 15%, and long or narrow duct costs more: one maker’s 8-inch blower drops from 831 to 709 CFM with a single bend. Use the delivered airflow, from the maker’s ducted rating or a measurement, when you plan the purge.
Should you supply or exhaust air in a confined space?
Supplying fresh air is the usual choice: it reaches the far end, mixes the space and keeps the worker in clean air. Exhaust suits a contaminant made at one point, such as welding fume, and must draw from where the gas collects: low for gases heavier than air like H₂S, high for lighter ones like methane.
What oxygen level is safe in a confined space in Canada?
Most jurisdictions require between 19.5% and 23% oxygen. Nova Scotia caps it at 22.5%, Newfoundland and Labrador requires 20% to 22%, and Yukon’s range runs to 23.5%. Normal air is 20.9%: a reading that has fallen means something has displaced or used up the oxygen.
Can ventilation replace atmospheric testing?
No. A calculation plans the ventilation; only a gas test shows the space is safe. Test at the top, middle and bottom before entry and monitor continuously while people are inside. Most Canadian jurisdictions require oxygen between 19.5% and 23%, and flammable gas below 10% or 20% of its lower explosive limit for work; pick yours in the calculator.